Skip Navigation
Skip to contents
Filter

ARTICLE TYPE

PUBLICATION DATE

14 results
Display

Therapeutic Drug Monitoring of Mycophenolic Acid

Yun YM, Kim JQ

  • KMID: 2040474
  • J Lab Med Qual Assur.
  • 2008 Dec;30(2):243-247.
No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Therapeutic Drug Monitoring of Tacrolimus and Sirolimus

Chun S, Lee W, Min WK

  • KMID: 2040473
  • J Lab Med Qual Assur.
  • 2008 Dec;30(2):241-242.
No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Therapeutic Drug Monitoring Consultation on Cyclosporine

Kim EY

  • KMID: 2040472
  • J Lab Med Qual Assur.
  • 2008 Dec;30(2):237-239.
No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Influence of Waist Circumference Index of Metabolic Syndrome on the Establishment of Reference Intervals

Ahn HJ, Jeon CI, Kim HR, Kim YA, Sun YK, Yoo JH

  • KMID: 2040482
  • J Lab Med Qual Assur.
  • 2008 Dec;30(2):301-306.
BACKGROUND: Metabolic syndrome is a combination of disorders that increase the risk of cardiovascular disease and type 2 diabetes. The aim of this study was to evaluate the influence of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of Dimension Hemoglobin A1c as an Emergency Outpatient Test

Park MJ, Shin MK, Song W

  • KMID: 2040477
  • J Lab Med Qual Assur.
  • 2008 Dec;30(2):267-271.
BACKGROUND: Hemoglobin A1c (HbA1c) is widely used for the diagnosis of diabetes and monitoring of glycemic control. Recently, there is an increasing demands of HbA1c as an emergency outpatient test....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Creatinine Determination with Minimized Interference

Chung HJ, Chun S, Min WK

  • KMID: 2040470
  • J Lab Med Qual Assur.
  • 2008 Dec;30(2):229-231.
Serum creatinine has been widely used clinically as an important index for kidney function. Kinetic Jaffe assay is used for serum creatinine analysis at about 80% of clinical laboratories in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of the Tosoh HLC-723 G8 HbA1c Autoanalyzer

Kwon A, Park JY, Kim JS

  • KMID: 2040478
  • J Lab Med Qual Assur.
  • 2008 Dec;30(2):273-277.
BACKGROUND: We evaluated overall performance and analysis time of newly developed HLC-723 G8 (Tosoh corp., Tokyo, Japan) HbA1c autoanalyzerwhich utilizes cation-exchange HPLC method. METHODS: Linearity, precision, correlation with Variant II Turbo...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Factors Affecting the Difference between the Low-Density Lipoprotein Cholesterol Concentrations Measured Directly and Calculated Using the Friedewald Formula

Min WK, Park HI, Jun KR, Chun S, Lee W

  • KMID: 2040471
  • J Lab Med Qual Assur.
  • 2008 Dec;30(2):233-235.
BACKGROUND: National Cholesterol Education Program Adult Treatment Panel III (NCEP ATP III) is the guideline for detection evaluation, and treatment of high blood cholesterol in adults. The risk of coronary...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of Green Vac-Tube in Clinical Laboratory Tests

Kim JY, Nam DH, Kim SH, Yang JH, Yoon SY, Lim CS, Lee CK, Cho YJ, Kim YK, Lee KN

  • KMID: 2040483
  • J Lab Med Qual Assur.
  • 2008 Dec;30(2):307-314.
BACKGROUND: Vacuum tubes are widely used in the clinical laboratory for routine tests. We compared a newly developed Green Vac-Tube (SPM, Gimje, Korea) with Vacutainer (BD, Franklin Lakes, NJ, USA)...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Relation between Microalbuminuria and Estimated Glomerular Filtration Rate by Creatinine and Cystatin C

Song Y, Park S, Seo Y, An J, Kim KH, Park P

  • KMID: 2040476
  • J Lab Med Qual Assur.
  • 2008 Dec;30(2):259-265.
BACKGROUND: In the routine "Life-turning point" medical checkup, we use estimated glomerular filtration rate (eGFR), which calculated from Cockcroft-Gault (CG) equation, to assume early stage renal disease and perform reexamination,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of the ABX Pentra DX 120 for the Detection of Immature Cells in Peripheral Blood

Lee YK, Kang HJ, Kim YM, Won CY, Cho HC

  • KMID: 2040475
  • J Lab Med Qual Assur.
  • 2008 Dec;30(2):249-258.
INTRODUCTION: The ABX Pentra DX 120 (Pentra DX 120, ABX Diagnostics, Montpellier, France) adopted new technologies to perform differential leukocyte and erythroblast counts. The double matrix can discriminate Large Immature...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Detection of Mutations in Chronic Hepatitis B Virus under Lamivudine Treatment: Direct Sequencing and CLIP Sequencing

Park H, Kwon HL, Song SH, Park KU, Song J, Park SS, Kim EC

  • KMID: 2040480
  • J Lab Med Qual Assur.
  • 2008 Dec;30(2):285-290.
BACKGROUND: Hepatitis B Virus (HBV) is a major risk factor for hepatocellular carcinoma, and about five to six percents of people are infected with HBV in Korea. Lamivudine is a...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of MRSASelect for Discrimination of Methicillin-resistant Staphylococcus aureus from Other Staphylococci

Kim YK, Kim JS, Lee HS, Song W, Kim HS, Park JY, Cho HC, Lee KM

  • KMID: 2040479
  • J Lab Med Qual Assur.
  • 2008 Dec;30(2):279-283.
BACKGROUND: It is now recognized that screening for methicillin-resistant Staphylococcus aureus (MRSA) in hospital is an effective infection control measure, and selective media-based methods have been commonly used. MRSASelect (MRSAS;...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical Effectiveness of Restriction Fragment Mass Polymorphism Assay for Human Papillomavirus Genotyping

Lee EH, Lee KB, Kim EO, Ji SI, Shin SK, Lee HS, Shim SY, Kim SO, Hong SP

  • KMID: 2040481
  • J Lab Med Qual Assur.
  • 2008 Dec;30(2):291-299.
BACKGROUND: Human papillomavirus (HPV) infection is the main cause of cervical cancer and with the advent of genotype specific vaccines, there is increased need for accurate, broad-spectrum and high-throughput methods...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr