Evaluation of Two Lateral-Flow Chromatographic Membrane Immunoassays for Rapid Detection of Influenza Virus in Limited Respiratory Specimens

Mai LQ, Hien PT, Hang NL, Oh JS, Ha GW, Kwon JA, Lee CK, Lee KN

  • KMID: 2200751
  • J Lab Med Qual Assur.
  • 2005 Dec;27(2):243-249.
BACKGROUND: The diagnosis of influenza based on clinical grounds alone may be inaccurate, because the presenting symptoms of influenza are similar to those caused by other infectious agents. We evaluate...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of C-peptide Test on Modular E170 Electrochemiluminescent Autoanalyzer

Lee SY, Hurh CB, Kang ES

  • KMID: 2200748
  • J Lab Med Qual Assur.
  • 2005 Dec;27(2):227-232.
BACKGROUND: C-peptide is a useful marker to differentiate the cause of hypoglycemia and assessment of beta cell secretory capacity in diabetes mellitus. On Modular E170 (E170, Roche Diagnostics, US), an...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Effect of Semen Contamination on the Urine Dipsticks

Cho YU, Lee HS, Hong TY, Choo IS, Oh DK, Choi MK

  • KMID: 2200749
  • J Lab Med Qual Assur.
  • 2005 Dec;27(2):233-236.
BACKGROUND: The dipstick methodology is the most fundamental urinalysis but interfered by many factors. We evaluated the effect of semen contamination on the urine dipsticks. METHODS: Thirty-two specimens for semen analysis...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of AutoLab(R) Reagents for Chemistry Analyzer

Kim YS, Lee HK, Kwon HJ, Min KO, Seo EJ, Kang CS

  • KMID: 2200743
  • J Lab Med Qual Assur.
  • 2005 Dec;27(2):203-210.
BACKGROUND: IVDLab corperation was established in 2000 and developed a liquid form reagents for clinical chemistry analyzer in 2001. So we evaluated the AutoLab(R) reagents produced by IVDLab corperation. METHODS: Sixteen...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of VITROS(R) 5,1 FS Automated Chemistry Analyzer

Yoon KJ, Kim JK, Jang JY

  • KMID: 2200745
  • J Lab Med Qual Assur.
  • 2005 Dec;27(2):211-218.
BACKGROUND: VITROS(R) 5,1 FS (Ortho-Clinical Diagnostics, NY, USA) is a newly developed, fully automated analyzer that uses the dry slide type technology to process routine chemistry items, electrolytes, therapeutic drug...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of Immunochemical Autoanalyzer Modular Analytics(R)

Cho CR, Um TH

  • KMID: 2200747
  • J Lab Med Qual Assur.
  • 2005 Dec;27(2):219-225.
BACKGROUND: We evaluated the performance of Modular Analytics (Roche Diagnostics, Basel, Switzerland) which is combined with automated chemiluminescent immunoassay analyzer and automated chemical analyzer in order to assess its...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Immunodiagnosis of Latent Tuberculosis through Interferon-gamma Measurement Following Stimulation of Tuberculosis-Specific Antigens (ESAT-6 and CFP-10)

Park KU, Lee HJ, Kim MJ, Lee KW, Kim JY, Kim HB, Choi EH, Lee JH, Lee CT, Song J

  • KMID: 2200750
  • J Lab Med Qual Assur.
  • 2005 Dec;27(2):237-242.
BACKGROUND:The tuberculin skin test, which has been used for years for the diagnosis of latent tuberculosis, has many limitations, including false-positive results in individuals who were vaccinated with BCG. We...