Maxillary protraction using customized mini-plates for anchorage in an adolescent girl with skeletal Class III malocclusion

Liang S, Xie X, Wang F, Chang Q, Wang H, Bai Y

The treatment of skeletal Class III malocclusion in adolescents is challenging. Maxillary protraction, particularly that using bone anchorage, has been proven to be an effective method for the stimulation of maxillary...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Radiologic Comparison of Humeral Position according to the Implant Designs Following Reverse Shoulder Arthroplasty: Analysis between Medial Glenoid/Medial Humerus, Lateral Glenoid/Medial Humerus, and Medial Glenoid/Lateral Humerus Designs

Cho NS, Nam JH, Hong SJ, Kim TW, Lee MG, Ahn JT, Rhee YG

BACKGROUND: The currently available reverse shoulder arthroplasty (RSA) designs can be classified into medial glenoid/medial humerus (MGMH), lateral glenoid/medial humerus (LGMH), and medial glenoid/lateral humerus (MGLH) prosthesis designs. The purpose...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Implant Design in Cementless Hip Arthroplasty

Kim JT, Yoo JJ

When performing cementless hip arthroplasty, it is critical to achieve firm primary mechanical stability followed by biological fixation. In order to achieve this, it is essential to fully understand characteristics...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A comparative study on the initial stability of different implants placed above the bone level using resonance frequency analysis

Kang IH, Kim CW, Lim YJ, Kim MJ

PURPOSE: This study evaluated the initial stability of different implants placed above the bone level in different types of bone. MATERIALS AND METHODS: As described by Lekholm and Zarb, cortical layers...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The effects of different pilot-drilling methods on the mechanical stability of a mini-implant system at placement and removal: a preliminary study

Cho IS, Choo H, Kim SK, Shin YS, Kim DS, Kim SH, Chung KR, Huang JC

OBJECTIVE: To investigate the effects of different pilot-drilling methods on the biomechanical stability of self-tapping mini-implant systems at the time of placement in and removal from artificial bone blocks. METHODS: Two...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of bone-implant contact pattern on bone strain distribution: finite element method study

Yoo DK, Kim SK, Koak JY, Kim J, Heo SJ

  • KMID: 2321782
  • J Korean Acad Prosthodont.
  • 2011 Jul;49(3):214-221.
PURPOSE: To date most of finite element analysis assumed the presence of 100% contact between bone and implant, which is inconsistent with clinical reality. In human retrieval study bone-implant contact...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Study on radiographic evaluation of marginal bone loss around osseointegrated implant after functional loading

Choi SJ, Chee YD, Koh SW

  • KMID: 1474224
  • J Korean Assoc Oral Maxillofac Surg.
  • 2009 Aug;35(4):240-247.
PURPOSE: The purpose of this study was to evaluate marginal bone loss to the bone crest functionally loaded for up to eighteen months and also with regard to other variables...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Marginal tissue response to different Implant neck design

Bae HE, Chung MK, Cha IH, Han DH

  • KMID: 2321751
  • J Korean Acad Prosthodont.
  • 2008 Dec;46(6):602-609.
STATEMENT OF PROBLEM: Loss of the marginal bone to the first thread have been accepted but continuous effort have been made to reduce this bone loss by varying implant design...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of implant designs on insertion torque and implant stability quotient (ISQ) value

Piao CM, Heo SJ, Koak JY, Kim SK, Han CH, Fang XH

  • KMID: 2000683
  • J Korean Acad Prosthodont.
  • 2006 Jun;44(3):325-332.
Statement of problem. Primary implant stability has long been identified as a prerequisite to achieve osseointegration. So the application of a simple, clinically applicable noninvasive test to assess implant...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Osteolysis in Cementless Total Knee Arthroplasty

Han CD, Lee WS

  • KMID: 2223386
  • J Korean Knee Soc.
  • 2000 Jun;12(1):7-13.
Eighty-four cementless primary total knee arthroplasties were performed from June 1989 to May 1993, and the prevalence and characteristics of osteolysis were determined after a mean follow-up of 6.4 years(range,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
THREE-DIMENSIONAL FINI6E ELEMENT ANALYSIS OF THE ENDOSSEOUS IMPLANT DESIGNS

Keun HY, Kwon JJ

  • KMID: 2196265
  • J Korean Acad Prosthodont.
  • 1997 Mar;35(1):181-210.
The stress distribution generated in the surrounding bone was calculated and compared for various geometry of the dental implants by means of the finite element methods. The models were designed...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close