Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

PUBLICATION DATE

13 results
Display

Risk Factors Associated with Failure of Cephalomedullary Nail Fixation in the Treatment of Trochanteric Hip Fractures

Yoo J, Chang J, Park C, Hwang J

BACKGROUND: Intramedullary (IM) nailing is widely performed in elderly patients with trochanteric fractures. Thus, it is important to identify causative factors associated with fixation failure. We investigated fixation failures after...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Fixation Failure of Proximal Femoral Nail Anti-rotation in Femoral Intertrochanteric Fracture

Lee KJ

PURPOSE: The aim of this study was to identify the causes of fixation failure and evaluate prophylactic methods in femoral intertrochanteric fractures treated with proximal femoral nail anti-rotation. MATERIALS AND METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Analysis of the Factors Involved in Failed Fixation in Elderly Intertrochanteric Femoral Fracture

Kang JS, Kim RS, Kim BS, Kim YT, Hong SH

PURPOSE: To analyze the causes of internal fixation failure in elderly intertrochanteric femoral fractures. MATERIALS AND METHODS: We retrospectively analyzed 93 intertrochanteric femoral fractures that were treated by internal fixation. The...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Analysis of the Fixation Failure in Intertrochanteric Hip Fractures Treated with Hip Nailing

Chang JD, Kim TY, Hwang JH, Min SK, Yoo JH

  • KMID: 2333522
  • J Korean Fract Soc.
  • 2012 Jul;25(3):169-176.
PURPOSE: To analyze the patterns of and risk factors for fixation failure after hip nailing in intertrochanteric (IT) hip fractures. MATERIALS AND METHODS: Fourteen patients who sustained a fixation failure after...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Anchor Hole Augmentation with Bone Cement in Arthroscopic Rotator Cuff Repair

Lee HM, Tae SK, Park JM

  • KMID: 2049485
  • Clin Should Elbow.
  • 2010 Dec;13(2):237-243.
PURPOSE: In arthroscopic rotator cuff repair, the crucial step is secure fixation of Anchor to bone. However, osteoporosis of the tuberosity is frequently encountered in old patients, and can cause...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Factors affecting Fixation Failure in Treatment of Intertrochanteric Fracture of the Femur by Dynamic Compression Hip Screw

Kim YS, Kwon SY, Han SK, Sung BY, Choi NY

PURPOSE: The purpose of this study was to analyze the factors affecting fixation failures of intertrochanteric fractures of the femur treated by dynamic compression hip screw in elderly patients. MATERIALS AND...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Analysis and Management of Failed Intertrochanteric Fracture Fixation

Suh DH, Han SB, Kang JW

PURPOSE: We wanted to analyze the causes of fixation failure after performing compression hip screw fixation for intertrochanteric fracture and we wanted to evaluate the methods to mange this type...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Analysis of Affecting Factors of Fixation Failure of Femoral Neck Fractures Using Internal Fixation

Yim SJ, Woo SH, Kim MY, Park JS, Kim EH, Seo YS, Lee BI

PURPOSE: To evaluate the factors which influence on the fixation failure after internal fixation using multiple cannulated screws in the patients with femoral neck fracture. MATERIALS AND METHODS: Ninty-six patients (male: 63,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Fixation Failure of LCP during the Treatment of Proximal Humerus Fractures

Min WK, Sin SJ, Jeon IH, Cha KB, Oh CW, Kim PT, Cheon SH

PURPOSE: To evaluate the causative factors in the catastrophic failure of LCP in the proximal humerus fracture. MATERIALS AND METHODS: Six patients (6 cases) were collected between October 2003 and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Fixation Failure of Unstable Intertrochanteric Fracture of the Femur Using Compression Hip Screw

Park SW, Lee SH, Baek JR, Park SJ, Chung JW

PURPOSE: To investigate the factors which influence on the fixation failure after the compression hip screw fixation for unstable intertrochanteric fractures. MATERIALS AND METHODS: Eighty-two patients of unstable intertrochanteric fracture of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Fixation Failure of Compression Hip Screw in Unstable Intertrochanteric Fracture of Femur

Hwang DS, Kwak SG, Kim YM, Nam DC, Hong UP

  • KMID: 2311705
  • J Korean Fract Soc.
  • 2003 Oct;16(4):600-604.
PURPOSE: To evaluate the factor of fixation failure in association of the early controlled weight bearing exercise after using a compression hip screw (CHS) for unstable intertrochanteric fracture of femur...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Common Modes of Fixation Failure with a Sliding Hip Screw encountered Unstable Intertrochanteric Fracture

Kim BS, Cho DY, Yoon HK, Sin DE, Han SH, Kim JH, Kim DJ

  • KMID: 2331040
  • J Korean Fract Soc.
  • 2003 Jan;16(1):15-21.
The purpose of this study was to evaluate the common modes of fixation failure in unstable intertrochanteric fractures , related risk factors and the prevention of fixation failure. Between 1995...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Fixation Failure after internal Fixation in Intertrochanteric Fractures

Lee JH, Yoon KS, Park JS, Kang SB, Moon SH

  • KMID: 2105233
  • J Korean Orthop Assoc.
  • 1997 Dec;32(7):1718-1724.
Fixation failure is a major complication of intertrochanteric fracture. The causes of fixation failure were assessed in a series of 80 patients with intertrochanteric fractures, which had been internally fixed...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top