Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

171 results
Display

Effect of implant diameter and cantilever length on the marginal bone height changes and stability of implants supporting screw retained prostheses: A randomized double blinded control trial

Khorshid HE, Issa NO, Ekram AM

PURPOSE. This randomized controlled trial aimed to evaluate the effect of implants’ two different diameters and cantilever lengths on the marginal bone loss and stability of mplants supporting maxillary prostheses....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Efficacy of Biometry Using Swept-source Optical Coherence Tomography for Posterior Chamber Phakic Intraocular Lens Implantation

Jo MS, Moon JY, Chung SK, Kim EK, Park KH, Choi JS

Purpose: The proper implantable collamer lens (ICL) size affects ICL stability. This study compared device efficacy using white-to-white diameter (WTW) measurements with Orbscan II and IOL Master 700. Methods: We retrospectively...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of interdental brush size and label information marketed in Korea

Cho YJ, Byon MJ, Jun EJ, Kang SM, Jeong SH

Objectives: This study compares the labeling information on the sizes of interdental brushes marketed in Korea to their actual sizes. Moreover, it analyzes the relationship between the size of the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Horizontal White-to-white Diameter Measured Using Four Devices

Yoon DE, Cho SC, Kim HJ, Han KE

Purpose: To compare the horizontal white-to-white (WTW) diameter measured using four devices. Methods: We measured the horizontal WTW diameter of 52 eyes of 52 patients using the IOL Master 500, ANTERION,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Survival Rate of Single Implant When Replacing the Mandibular Second Molars: Importance of Implant Length

Kim MJ, Chang HJ, Ahn KM

Purpose: Restoration of the mandibular second molar with single implants has many limitations. This includes poor bone quality, reduced alveolar bone, large occlusal force, and difficulty in surgical approach. The purpose...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison between the coronal diameters of the cervical spinal canal and spinal cord measured using computed tomography and magnetic resonance imaging in Korean patients

Lee SY, Kim IY, Jeong KW, Ryu T, Kwak SK, Jung JY

Background: If the proportion of the spinal cord in the epidural space can be determined under C-arm fluoroscopy during cervical epidural block, a safe entry point for the epidural needle...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Heparin Immobilization of Tissue Engineered Xenogeneic Small Diameter Arterial Scaffold Improve Endothelialization

Tardalkar K, Marsale T, Bhamare N, Kshersagar J, Chaudhari L, Joshi MG

BACKGROUND: Autologous vessels graft (Inner diameter \ 6 mm) harvesting always challenged during bypass grafting surgery and its complication shows poor outcome. Tissue engineered vascular graft allow to generate biological...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of the effects of normal and low blood pressure regulation on the optic nerve sheath diameter in robot assisted laparoscopic radical prostatectomy

Park JH, Hong JH, Kim JS, Kim HJ

Background: Robot-assisted laparoscopic radical prostatectomy is an advanced and popular surgical technique. However, increased intracranial pressure which is caused by CO2 pneumoperitoneum and Trendelenburg position is the main cerebrovascular effect....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Real-time change of optic nerve sheath diameter after rebleeding of ruptured intracranial dissecting aneurysm

Koo HW

Ultrasonographic measurement of optic nerve sheath diameter (ONSD) has been validated to detect and monitor the increased intracranial pressure (IICP) in neurosurgical field. Especially, the ONSD has been known to...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Long-Term Substance Use Can Cause Irreversible Photopic Vision Changes in Substance Use Disorder in Remission

Egilmez OB, Orum MH, Kustepe A, Karadag AS, Kalenderoglu A

Objective Substance use has such effects on pupil diameter. Although there is knowledge about the acute effects of substances on pupils, studies showing their chronic effects are limited. The aim...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Alterations in Growth and Morphology of Ganoderma lucidum and Volvariella volvaceae in Response to Nanoparticle Supplementation

Singh S, Kuca K, Kalia A

Use of nanoparticles (NPs) in several commercial products has led to emergence of novel contaminants of air, soil and water bodies. The NPs may exhibit greater ecotoxicity due to nano-scale...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Preliminary study for fully digitally guided implant treatment with narrow implants in the anterior region

Kang JS, Heo Hy, Son MK

The aim of this study was to evaluate the survival rates of narrow implants placed in the maxillary or mandibular anterior region with digitally guided flapless surgery and prosthetic system....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Prognostic Value of Dual-Energy CT-Based IodineQuantification versus Conventional CT in AcutePulmonary Embolism: A Propensity-Match Analysis

Im DJ, Hur J, Han K, Suh YJ, Hong YJ, Lee HJ, Kim YJ, Choi BW

Objective: The present study aimed to investigate whether quantitative dual-energy computed tomography (DECT) parametersoffer an incremental risk stratification benefit over the CT ventricular diameter ratio in patients with acute pulmonary...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Intranasal Oxytocin Increases Perceptual Salienceof Faces in the Absence of Awareness

Xue SW, Wu HB, Zhang L, Zhang DX

Objective The neuropeptide oxytocin has been found to improve human social cognition and promote prosocial behavior. However, it is still unclear about the mechanisms underlying these effects of oxytocin on neural...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Screening of the growth of thymus of human fetuses

Asghar A, Asad MR, Naaz S, Rani M

The thymus is a lymphoepithelial organ, and its morphometry is commonly utilized for surveillance of the immunological status of fetus and neonates. Many studies showed that fetal thymus size is...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A cadaveric study of ovarian veins: variations, measurements and clinical significance

Ghosh A, Chaudhury

The literature showing information regarding ovarian venous variation, its diameter and termination distance from respective renal venous origin are limited. This information is important in various surgical and clinical procedures...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Huge Vertebrobasilar Dolichoectasia

Kim BS, Lee JG, Ahn S, Park JH

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Retrospective Observational Study of Narrow Diameter Implants

Lee JG, Kang DW, Yun PY, Kim YK

PURPOSE: To Analyse clinical treatment outcomes and prognosis of patients who have received narrow diameter implants due to anterior tooth loss, and to assess long-term success measured through radiological examination. MATERIAL...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Structural and Functional Features on Quantitative Chest Computed Tomography in the Korean Asian versus the White American Healthy Non-Smokers

Cho HB, Chae KJ, Jin GY, Choi J, Lin CL, Hoffman EA, Wenzel SE, Castro M, Fain SB, Jarjour NN, Schiebler , Barr RG, Hansel N, Cooper CB, Kleerup EC, Han MK, Woodruff P, Kanner RE, Bleecker E, Peters SP, Moore WC, Lee CH, Choi S, the National Heart, Lung and Blood Institute's SubPopulations and InteRmediate Outcome Measures In COPD Study (SPIROMICS) and Severe Asthma Research Program (SARP)

OBJECTIVE: Considering the different prevalence rates of diseases such as asthma and chronic obstructive pulmonary disease in Asians relative to other races, Koreans may have unique airway structure and lung...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of apical constriction diameter, irrigant flow rate, and needle tip design on apical pressure

Lee CH, Jo SA, Lim BS, Lee IB

The purpose of this study was to evaluate the effects of apical constriction (AC) diameter, irrigant flow rate, and needle tip design on apical pressure (AP) during the root canal...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2023 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr