Skip Navigation
Skip to contents
Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

12 results
Display

Whatever Your Preference Is for the Treatment of the Proximal Humeral Fracture

Cho NS

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Overview of Various Measurement Tools for Shoulder Kinematics

Kim DS, On MG, Yeom JS

Shoulder kinematics is important, as it is associated with shoulder arthropathy and pain mechanisms. Various static and dynamic analysis methods are prevalent for shoulder kinematics. These include 2-dimensional plane x-ray,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Two Arthroscopic Coracoplasty Approaches in Subscapularis Tears

Song HE, Jang SH, Kim JG

BACKGROUND: Few studies have reported the results of arthroscopic coracoplasty concomitantly conducted with subscapularis tear. Therefore, this study was conducted to examine and compare the outcomes of arthroscopic subscapularis repair...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Hook Plate Fixation for Isolated Greater Tuberosity Fractures of the Humerus

Lee KR, Bae KC, Yon CJ, Cho CH

BACKGROUND: The purpose of this study was to investigate the outcomes after fixation using a 3.5-mm locking compression plate (LCP) hook plate for isolated greater tuberosity (GT) fractures of the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Intra-articular Lesions and Clinical Outcomes in Traumatic Anterior Shoulder Dislocation Associated with Greater Tuberosity Fracture of the Humerus

Lim KP, Lee IS, Kim IB

BACKGROUND: This study investigated and evaluated the clinical outcomes of intra-articular lesions of traumatic anterior shoulder dislocation (TASD) associated with greater tuberosity (GT) fracture of the humerus. METHODS: Subjects included 20...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Repair Integrity and Functional Outcomes after Arthroscopic Repair of Transtendinous Full-thickness Rotator Cuff Tears Minimum Two-year Follow-up

Kim KC, Lee WY, Shin HD, Kim YM, Han SC

BACKGROUND: To evaluate the clinical outcomes and associated repair integrity in patients treated with arthroscopic repair for a transtendinous rotator cuff tear followed by resection of the remnant rotator cuff...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Anatomical Locking Plate with Additional K-wire Fixation for Distal Clavicle Fracture

Nam WD, Moon SH, Choi KY

BACKGROUND: Neer type II distal clavicle fractures have the drawback of coracoclavicular instability and insufficient distal bony fragment, thereby making it difficult to achieve adequate fixation. Although various surgical treatments...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Compartment Syndrome of the Upper Extremity Induced by Extravasation of Contrast Media after Computed Tomography: A Case Report

Jung JW, Lim YJ, Kim BS, Cho CH

The incidence of contrast media extravasation has been increasing gradually. Most contrast media extravasations only can cause pain, swelling and erythema. However, in more severe cases, skin necrosis, ulceration, or...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Internal Fixation with a Locking T-Plate for Proximal Humeral Fractures in Patients Aged 65 Years and Older

Yum JK, Seong MK, Hong CW

BACKGROUND: The purpose of this study was to evaluate the clinical and radiographic outcomes of internal fixation with locking T-plates for osteoporotic fractures of the proximal humerus in patients aged...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Ulnar Nerve Injury Caused by the Incomplete Insertion of a Screw Head after Internal Fixation with Dual Locking Plates in AO/OTA Type C2 Distal Humerus Fractures

Shin JH, Kwon WJ, Hyun YS

After dual plating with a locking compression plate for comminuted intraarticular fractures of the distal humerus, the incidence of ulnar nerve injury after surgery has been reported to be up...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Advantages of Scorpion Suture Passer and 70 Degrees Arthroscope in Arthroscopic Bankart Repair: Usefulness for Inferior Labral Repair

Hyun YS, Shin WJ

BACKGROUND: The blunted tip of a reusable with multiple uses can cause problems with the passing procedure in arthroscopic Bankart repair. This study assessed the advantage of Scorpion with a...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical and Radiologic Results Comparing the Periarticular Proximal Humerus Locking Plate and Polarus Nail for Displaced Proximal Humerus Fractures

Min YK, Lee SJ, Gwak HC, Kang SW, Suh KT

BACKGROUND: This study compared the clinical and radiological outcomes of the single calcar screw plate and Polarus nail techniques for the treatment of the proximal humerus fractures. METHODS: Seventy-two patients diagnosed...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr