Comparison of Cardiac Output Measured by Impedance Cardiography and Thermodilution in Open Heart Surgery

Park JC, Ham BM

BACKGROUND: Impedance Cardiography is a noninvasive and simple method of cardiac output determination. The purpose of this study was to compare an impedance device with the thermodilution method during the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Impedance Cardiography with Thermodilution of Hemodynamic Parameters in Critically Ill Patients

Kang HG, Chung SW, Byun KH, Kim IB

  • KMID: 1513796
  • Korean J Crit Care Med.
  • 2006 Dec;21(2):77-82.
BACKGROUND: To evaluate the feasibility of noninvasive hemodynamic monitoring (impedance cardiography, ICG) in critically ill patients, we compared this technique with simultaneous invasive monitoring with a pulmonary artery thermodilution catheter. METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Changes of cardiac output during treadmill exercise by impedance cardiography

Hwang SK, Kim DW, Ko SK, Kim CK

Nine athletes and ten nonathletes were selected randomly to study the changes of cardiac function during exercise by impedance cardiography. The speed of the treadmill was maintained at 3.4 mph,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Cardiac Output and the Cardiac Muscle Contractility During Postural Gradient Changes by Tilt Table in Man

Ko SK

  • KMID: 1591897
  • Korean J Aerosp Environ Med.
  • 2001 Dec;11(4):208-214.
The purpose of this study is to investigate changes of the cardiac output and the cardiac muscle contractility during postural gradient changes in man. Subjects consisted of 15 healthy males...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Detection of physiological events by impedance

Kim DW

The current emphasis on the acquisition of physiological data by noninvasive means for mass medical screening and patient monitoring has increased interest in the use of electrical impedance for the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Measurement of Hemodynamic Variables using Impedance Cardiography on Remifentanil-Propofol Infusion during Anesthetic Induction

Cheong SH, Park TS, Lee SE, Kim YH, Lim SH, Lee JH, Lee KM, Choe YK, Kim YJ, Shin CM

BACKGROUND: Remifentanil-propofol combination is used to minimize the cardiovascular responses during anesthetic induction; however, it may generate side effects such as hypotension or bradycardia. The authors investigated the changes of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Accuracy and Efficacy of Impedance Cardiography as a Non-Invasive Cardiac Function Monitor

Kim GE, Kim SY, Kim SJ, Yun SY, Jung HH, Kang YS, Koo BN

PURPOSE: The most common method of monitoring cardiac output (CO) is thermodilution using pulmonary artery catheter (PAC), but this method is associated with complications. Impedance cardiography (ICG) is a non-invasive...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Comparison of Bioimpedance and Echocardiography in Measuring Cardiac Output in Healthy Male Volunteers

Cho GC, Kim W, Sohn YD, Kang HD, Oh BJ, Lim KS

  • KMID: 1898809
  • J Korean Soc Emerg Med.
  • 2006 Jun;17(3):225-230.
PURPOSE: To manage a critically ill patient effectively, an emergency physician must make an accurate assessment of the patient's hemodynamic status. Although the hemodynamic status can be accurately measured through...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Noninvasive Cardiac Output Measurement in Shock Patients

Kim OH, Choi HJ, Kim H, Lee KH, Hwang SO

  • KMID: 1997741
  • J Korean Soc Emerg Med.
  • 2010 Oct;21(5):594-599.
PURPOSE: Invasive determination of cardiac output (CO) is possible via a pulmonary artery catheter but catheter implantation has risks. Clinicians can assess CO safely using a non-invasive cardiac output device...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical Significance of B-type Natriuretic Peptide Levels and Impedance Cardiography in Maintenance Hemodialysis Patients

Han BG, Kim MS, Yu JM, Han ST, Choi SO

  • KMID: 2307241
  • Korean J Nephrol.
  • 2005 Sep;24(5):797-804.
BACKGROUND: The risk for cardiovascular morbidity and mortality is higher in hemodialysis (HD) patients than in general population. Early diagnosis, treatment and prevention of cardiovascular disease (CVD) are the best...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Systolic time ratio measured by impedance cardiography accurately screens left ventricular diastolic dysfunction in patients with arterial hypertension

Nazário Leão R, Marques Silva P, Branco L, Fonseca H, Bento B, Alves M, Virella D, Palma Reis R

BACKGROUND: The use of impedance cardiography (ICG) may play a role in the assessment of cardiac effects of hypertension (HT), especially its hemodynamic features. Hypertensive heart disease involves structural changes...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Hemodynamic Changes during Heas-Down and Up Tilt after Ethanol Ingestion

Kim JY, Kim HJ, Hong JG

BACKGROUND: The acute effect, of ethanol (EOH) include lowered blood pressure through peripheral vasodilation and decreased circulating blood volume. This study was aimed at examing the effects of EOH on...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Cardiac response to head-out water immersion in man

Choi JK, Park WK

  • KMID: 1580812
  • Korean J Physiol Pharmacol.
  • 2000 Jun;4(3):253-261.
Head-out water immersion induces marked increase in the cardiac stroke volume. The present study was undertaken to characterize the stroke volume change by analyzing the aortic blood flow and left ventricular systolic time...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A comparison of hemodynamics in elderly patients that were administered thiopental sodium or propofol to induce general anesthesia

Kim MH, Kim DK, Lee JW, Lim HS, Han YJ, Kim DC

BACKGROUND: Thiopental sodium and propofol are commonly used to induce anesthesia. This study was conducted to compare the hemodynamic effects of propofol and thiopental sodium during the induction of general...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Measurements of Cardiac Output by Electrical Impedance and Thermodilution in Coronary Artery Bypass Graft Patients

Kim HK, Park HH, Ham BM

Simultaneous perioperative measurements of cradiac output were obtained in 16 patients for coronary artery bypass graft with transthoracic impedance and pulmonary artery thermodilution techniques to evaluate the utility of the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Paddle-skin Coupling Material Usage in Emergency Institutes in South Korea

Lee MH, Kim AJ, Park JS, Roh JY, Kim KH, Shin DW, Lee KM, Park SU, Kim YK

  • KMID: 1997816
  • J Korean Soc Emerg Med.
  • 2010 Feb;21(1):125-130.
PURPOSE: While the use of coupling material (CM) during defibrillation is known to decrease transthoracic impedance more so than other materials elsewhere, the situation in Korea is unclear. The study...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Changes of Noninvasive Hemodynamic Parameters after Device-Guided Slow Breathing Exercise in Hypertensive Patients

Kim JY, Yoo BS, Lee SH, Yoon J, Choe KH

BACKGROUND: The device-guided breathing (DGB) exercise is a non-pharmacological treatment of high blood pressure (BP). Changes in hemodynamic variables after DGB remain to be defined. This study evaluated the hemodynamic...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close