Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

204 results
Display

Effect of surface treatments and universal adhesive application on the microshear bond strength of CAD/CAM materials

Şişmanoğlu S, Gürcan AT, Yıldırım-Bilmez Z, Turunç-Oğuzman R, Gümüştaş B

PURPOSE: The aim of this study was to evaluate the microshear bond strength (µSBS) of four computer-aided design/computer-aided manufacturing (CAD/CAM) blocks repaired with composite resin using three different surface treatment...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of Saliva Decontamination on Bond Strength of 1-step Self-etching Adhesives to Dentin of Primary Posterior Teeth

Lee J, Kim S, Jeong T, Shin J, Lee E, Kim J

The purpose of this study was to evaluate effect of saliva decontamination procedures on microtensile bond strength (MTBS) of 1-step self-etching adhesives to dentin of primary posterior teeth. 63 sound primary-posterior...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Influence of different universal adhesives on the repair performance of hybrid CAD-CAM materials

Demirel G, Baltacıoğlu IH

OBJECTIVES: The aim of this study was to investigate the microshear bond strength (μSBS) of different universal adhesive systems applied to hybrid computer-aided design/computer-aided manufacturing (CAD-CAM) restorative materials repaired with...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Cauda Equina Syndrome Occurred by Adhesive Arachnoiditis of the Lumbar Spine with an Unknown Cause

Jeon HS, Hwang SH, Suh SP, Kim JN

Spinal adhesive arachnoiditis is an inflammation and fibrosis of the subarachnoid space and pia mater caused by infection, trauma, spinal vascular anomalies, and iatrogenic (surgery and/or puncture). Adhesive arachnoiditis develops...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Shear-Wave and Strain Ultrasound Elastography of the Supraspinatus and Infraspinatus Tendons in Patients with Idiopathic Adhesive Capsulitis of the Shoulder: A Prospective Case-Control Study

Yun SJ, Jin W, Cho NS, Ryu KN, Yoon YC, Cha JG, Park JS, Park SY, Choi NY

OBJECTIVE: To compare the elasticity of the supraspinatus tendon (SST) and infraspinatus tendon (IST) in patients with idiopathic adhesive capsulitis of the shoulder (ACS) with those in the control groups...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of adhesive strength of resinous teeth splinting materials according to enamel surface treatment

Lee YR, Kim SY, Kim JW, Park SH, Cho KM

PURPOSE: The purpose of this study is to compare and analyze the shear bond strength and fracture pattern in different enamel tooth surface treatments for resin splinting materials. MATERIALS AND METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
In vivo optical coherence tomographic imaging to monitor gingival recovery and the adhesive interface in aesthetic oral rehabilitation: A case report

Graça ND, Palmeira A, Fernandes , Pedrosa MD, Guimarães RP, dos Santos SC, Gomes AS, da Silva C

The available methods for veneer evaluation are limited to clinical and radiographic examinations, which may not allow the appropriate identification of failure. In this report, we demonstrate the use of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Influence of Application Method on Shear Bond Strength and Microleakage of Newly Developed 8th Generation Adhesive in Primary Teeth

Ryu W, Park H, Lee J, Seo H

The purpose of this study was to evaluate the effect of application time and phosphoric acid etching of 8th generation adhesives containing functional monomer on adhesive performance in primary teeth. 80...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Influence of silver nanoparticles on resin-dentin bond strength durability in a self-etch and an etch-and-rinse adhesive system

Jowkar Z, Shafiei F, Asadmanesh E, Koohpeima

OBJECTIVES: This study evaluated the effect of dentin pretreatment with silver nanoparticles (SNPs) and chlorhexidine (CHX) on the microshear bond strength (µSBS) durability of different adhesives to dentin. MATERIALS AND METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of pre-curing of two universal adhesives on the shear bond strength of resin cement to zirconia

Son GE, Kwon TY, Kim YK

This study aimed to investigate whether pre-curing the universal adhesives affect the resin bonding to zirconia ceramic. Two commercial universal adhesives (All-Bond Universal, ABU; Single Bond Universal Adhesive, SBU) were...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Do We Have to Perform Surgical Treatment Simultaneously for Rotator Cuff Tear in Patients with Adhesive Capsulitis?

Kang SW

PURPOSE: Retrospectively, the purpose of this study is to investigate the necessity for early operation for patients with rotator cuff tears and concomitant adhesive capsulitis. METHODS: From March 2013 to March...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Computed Tomography Arthrography Findings of Idiopathic Adhesive Capsulitis of the Hip: An Analog of Adhesive Capsulitis of the Shoulder

Lee GY, Ha YC, Kim S, Kim JY

OBJECTIVE: To identify useful imaging findings for the diagnosis of idiopathic adhesive capsulitis of the hip (ACH) on computed tomography arthrography (CTA). MATERIALS AND METHODS: Twenty-eight consecutive patients (29 hips; 7...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Bracket bonding to polymethylmethacrylate-based materials for computer-aided design/manufacture of temporary restorations: Influence of mechanical treatment and chemical treatment with universal adhesives

Goracci C, Özcan M, Franchi L, Di Bello G, Louca C, Vichi A

OBJECTIVE: To assess shear bond strength and failure mode (Adhesive Remnant Index, ARI) of orthodontic brackets bonded to polymethylmethacrylate (PMMA) blocks for computer-aided design/manufacture (CAD/CAM) fabrication of temporary restorations, following...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical Outcome after Arthroscopic Capsular Release for Adhesive Capsulitis of the Shoulder

Yoo JC, Koh KH, Shon MS, Bae KH, Lim TK

BACKGROUND: This study was undertaken to evaluate the outcome of the arthroscopic capsular release for adhesive capsulitis of the shoulder. METHODS: This study retrospectively investigated thirty shoulders in 29 patients who...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Impact of Double Fixation with Titanium Tack and N-Butyl Cyanoacrylate Glue (NBCG) Mesh Fixation versus NBCG Fixation Only in Totally Extra-Peritoneal Hernioplasty with 3-Dimensional Configured Polyester Mesh: A Comparative Study

Chen K, Liu J, Yang X, Fan JK, MBBS MS (HKU) FRCSEd

PURPOSE: Our aim is to compare 3-dimensional mesh fixation using titanium tacks combine with n-butyl cyanoacrylate glue (NBCG) (COMBINE group) versus NBCG only (NBCG group) in totally extraperitoneal inguinal hernioplasty...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Impact of Double Fixation with Titanium Tack and N-Butyl Cyanoacrylate Glue (NBCG) Mesh Fixation versus NBCG Fixation in Totally Extra-Peritoneal Hernioplasty with 3-Dimensional Configured Polyester Mesh: A Comparative Study

Seo KW

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of surface pre-treatments and adhesive types on the shear bond strength between PEKK and Zirconia

Jung AM, Kim SM

In this study, the effects of surface pre-treatment and adhesive type on the shear bond strength between PEKK (polyetherketoneketone) and zirconia were analyzed by means of shear bond test and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of Fluoride Recharging on Fluoride Release and Surface Properties of Orthodontic Bracket Adhesives

Byeon SM

The aim of this study was to compare fluoride release and surface changes according to different orthodontic bracket adhesives the application of fluoride products. We used non-fluoridated composite resin Transbond...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Influence of nonthermal argon plasma on the shear bond strength between zirconia and different adhesives and luting composites after artificial aging

Pott PC, Syväri TS, Stiesch M, Eisenburger M

PURPOSE: Plasma activation of hydrophobic zirconia surfaces might be suitable to improve the bond strength of luting materials. The aim of this study was to analyze the influence of nonthermal...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Do universal adhesives promote bonding to dentin? A systematic review and meta-analysis

Elkaffas A, Hamama HH, Mahmoud SH

OBJECTIVES: The aims of this study were to conduct a systematic review of the microtensile bond strength (µTBS) of multi-mode adhesives to dentin and to perform a meta-analysis to assess...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2021 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr