Intermittent, Non Cyclic Severe Mechanical Aortic Valve Regurgitation

Choi JH, Choi JH, Song S, Lee MY

Mechanical aortic prosthesis dysfunction can result from thrombosis or pannus formation. We describe an unusual case of intermittent, non cyclic mechanical aortic prosthesis dysfunction due to pannus formation with thrombus...