Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

164 results
Display

An evaluation of the stress effect of different occlusion concepts on hybrid abutment and implant supported monolithic zirconia fixed prosthesis: A finite element analysis

Yesilyurt NG, Tuncdemir AR

PURPOSE The aim of this study is to evaluate the effects of canine guidance occlusion and group function occlusion on the degree of stress to the bone, implants, abutments, and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Bone loss-related factors in tissue and bone level dental implants: a systematic review of clinical trials

Mortazavi H, Khodadoustan A, Kheiri A, Kheiri L

Dental implants are popular for dental rehabilitation after tooth loss. The goal of this systematic review was to assess bone changes around bone-level and tissue-level implants and the possible causes....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Pull-off resistance of a screwless implantabutment connection and surface evaluation after cyclic loading

Alevizakos V, Mosch R, Mitov G, Othman A, See Cv

Purpose The aim of this study was to investigate to what extent cyclic load affects the screwless implant-abutment connection for Morse taper dental implants. Materials and Methods 16 implants (SICvantage...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Implant-supported Full Mouth Rehabilitation Using Customized Non-precious Metal Casting Abutments: A Case Report

Kim S, Lee JI

When treating an edentulous patient, it is difficult to rehabilitate and maintain long-term functionality with an implant-supported fixed prosthesis. This is because resorption of the remaining alveolar bone may cause...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of fluid contamination on reverse torque values in implant-abutment connections under oral conditions

Mostafavi AS, Memarian M, Seddigh MA

Purpose Implant mechanical complications, including screw loosening, can influence dental implant success. It has been shown that torque values are affected by contamination occurred in implant-abutment (I/A) interface. This study...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The influence of the implant-abutment complex on marginal bone and peri-implant conditions: A retrospective study

Tokgöz SE, Bilhan H

Purpose The design of the implant-abutment complex is thought to be responsible for marginal bone loss (MBL) and might affect the condition of the peri-implant tissues. This the present study...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The use of implant-assisted removable partial denture in the partially edentulous maxilla with a few unilateral remaining teeth and implant overdenture in the mandible: A case report

Yun Y, Kim HA, Park S, Park C, Jang W

Successful cases of the implant-assisted removable partial denture and implant overdentures are reported in which a few implants are additionally placed to secure the maintenance, support, and stability of the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Restoration of implant-supported fixed dental prosthesis using the automatic abutment superimposition function of the intraoral scanner in partially edentulous patients

Park KW, Park JM, Lee KW

The digital workflow of optical impressions by the intraoral scanner and CADCAM manufacture of dental prostheses is actively developing. The complex process of traditional impression taking, definite cast fabrication, wax...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Abutment-Level Digital Impression Using Abutment Matching Algorithm, And Insurance-Covered Implant Prosthesis By Metal 3D Printing: A Case Report

Kang IH, Park JM, Shim JS

In the process of manufacturing implant-fixed prostheses, it has traditionally required complicated procedures such as impression taking, master cast fabrication, wax-up and so on, but recently, digital impression with an...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of the effect of abutment preparation angles on the repeatability and reproducibility using a blue light model scanner

Kim DY

PURPOSE. The purpose of the study is to evaluate the repeatability and reproducibility of the abutment angle using a blue light scanner. MATERIALS AND METHODS. 0°, 6°, and 10° wax...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Influence of implant mucosal thickness on early bone loss: a systematic review with meta-analysis

Gianfilippo RD, Valente NA, Toti P, Wang HL, Barone A

Purpose: Marginal bone loss (MBL) is an important clinical issue in implant therapy. One feature that has been cited as a contributing factor to this bone loss is peri-implant mucosal...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The biocompatibility and mechanical properties of plasma sprayed zirconia coated abutment

Huang Z, Wang Z, Yin K, Li C, Guo M, Lan J

PURPOSE. The aim of this study was to evaluate the clinical performance and reliability of plasma sprayed nanostructured zirconia (NSZ) coating. MATERIALS AND METHODS. This study consisted of three areas...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Joint stability of internal conical connection abutments with or without hexagon indexes: an in vitro study

Lee SW, Cha MS, Lee JH, Cho LR, Park CJ

Purpose: The purpose of this study was to compare the axial displacement of the hexagonal and conical abutment in internal conical connection implant after screw tightening and cyclic loading. Materials...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Study of the fracture resistance of zirconia on posterior fixed partial dentures based on inter-abutment distance

Park GB, Shin SY

Purpose: Zirconia fixed partial dentures with mandibular 2nd premolar and 2nd molar as abutments are fabricated and then the effects of inter-abutment distance on fracture resistance of zirconia fixed partial...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical accuracy of impression technique using digital superimposition ofcustomized abutment with subgingival margin: A case report

Kim JW, Jeong CM, Yun MJ, Lee SH, Lee H, Huh JB

Traditionally, gingival retraction has been performed to obtain customized abutment impressions with subgingival margins of the implant supported prosthesis. However, gingival retraction may have side effects such as gingival recession and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of the accuracy of implant digital impression coping

Ahn GZ, Lee JS

Purpose: The purpose of this study was to compare the accuracy of impression taking method using the encoded healing abutment, scan body and pick-up impression coping with different implant angulations....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Concept and application of implant connection systems: Part II. Placement and restoration of external connection implant and tissue level implant

Ko KH, Kang HG, Huh YH, Park CJ, Cho LR

To use the external connection implant (EXT) appropriately, the inter-implant distance should be carefully considered during placement, and the bones raised above the implants should be trimmed during the second...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Biomechanical stress and microgap analysis of bone-level and tissue-level implant abutment structure according to the five different directions of occlusal loads

Kim JH, Noh Gw, Hong SJ, Lee Hj

PURPOSE The stress distribution and microgap formation on an implant abutment structure was evaluated to determine the relationship between the direction of the load and the stress value. MATERIALS AND METHODS Two...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Radiographic evaluation of marginal bone level alteration around narrow implants placed in narrow alveolar ridge using guided flapless surgery

Jeong SM, Choi BH

Purpose: The aim of this study was to compare radiographic outcomes around narrow-diameter implants placed using guided flapless surgery at longer than 6 month postplacement. Materials and Methods: A total of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Implant-assisted removable partial denture using freely removable abutment in a fully edentulous patient: A case report

Oh YK, Jeong CM, Yun MJ, Lee SH, Lee HJ, Huh JB

Implant-Assisted Removable Partial Dentures (IARPDs) treatment is being performed in a fully edentulous patient using implant surveyed prosthesis as an abutment. Implant-supported prosthesis as an abutment of IARPDs is classified...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2021 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr