Skip Navigation
Skip to contents
Filter

ARTICLE TYPE

PUBLICATION DATE

13 results
Display

Immediate fixed partial denture after tooth extraction in patients with systemic diseases: A clinical report

Kang HS, Lee SY

For patients with systemic diseases who face difficulties visiting dental clinics, wearing fixed partial denture in the anterior region on the same day of tooth extraction can reduce the total...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Contour of lingual surface in lower complete denture formed by polished surface impression

Heo YR, Kim HJ, Son MK, Chung CH

PURPOSE: The aim of this study was to analyze the shapes of lingual polished surfaces in lower complete dentures formed by polished surface impressions and to provide reference data for...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of surface treatment methods on the shear bond strength of auto-polymerized resin to thermoplastic denture base polymer

Koodaryan , Hafezeqoran A

PURPOSE: Polyamide polymers do not provide sufficient bond strength to auto-polymerized resins for repairing fractured denture or replacing dislodged denture teeth. Limited treatment methods have been developed to improve the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of the fit accuracy of zirconia-based prostheses generated by two CAD/CAM systems

Ha SJ, Cho JH

PURPOSE: The purposes of this study are to evaluate the internal and marginal adaptation of two widely used CAD/CAM systems and to study the effect of porcelain press veneering process...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of cement type on the color attributes of a zirconia ceramic

Tabatabaian F, Habib Khodaei M, Namdari M, Mahshid M

PURPOSE: This in vitro study evaluated the effects of four different cements on the color attributes of a zirconia ceramic. MATERIALS AND METHODS: 40 zirconia ceramic disk specimens (0.5 mm thickness,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of stability of interface between CCM (Co-Cr-Mo) UCLA abutment and external hex implant

Yoon KJ, Park YB, Choi H, Cho Y, Lee JH, Lee KW

PURPOSE: The purpose of this study is to evaluate the stability of interface between Co-Cr-Mo (CCM) UCLA abutment and external hex implant. MATERIALS AND METHODS: Sixteen external hex implant fixtures were...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The prognosis of splinted restoration of the most-distal implants in the posterior region

Lee JB, Kim MY, Kim CS, Kim YT

PURPOSE: The aim of this study was to compare the efficacies of two-implant splinting (2-IS) and single-implant restoration (1-IR) in the first and second molar regions over a mean functional...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Mechanical properties related to the microstructure of seven different fiber reinforced composite posts

Alonso de la Peña V, Darriba IL, Caserío Valea M, Guitián Rivera F

PURPOSE: The aim of this in vitro study was to evaluate the mechanical properties (bending strength and hardness) of seven different fiber reinforced composite posts, in relation to their microstructural...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Color variation induced by abutments in the superior anterior maxilla: an in vitro study in the pig gingiva

Atash R, Boularbah , Sibel C

PURPOSE: The aim of this work is to evaluate different types of materials used for making implant abutments, by means of an in vitro study and a review of the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A comparison of the fracture resistances of endodontically treated mandibular premolars restored with endocrowns and glass fiber post-core retained conventional crowns

Guo J, Wang Z, Li X, Sun C, Gao E, Li H

PURPOSE: This in-vitro study aimed to evaluate the fracture resistances and failure modes of endodontically treated mandibular premolars restored with endocrowns and conventional post-core retained crowns. MATERIALS AND METHODS: Thirty mandibular...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparing a tablet computer and paper forms for assessing patient-reported outcomes in edentulous patients

Caetano TA, Ribeiro AB, Della Vecchia MP, Cunha TR, Chaves CD, de Souza R

PURPOSE: The aim of this study was to determine whether two methods of documentation, print and electronic forms, for the assessment of patient-reported outcomes (PRO) in complete denture wearers provide...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The effects of different polishing techniques on the staining resistance of CAD/CAM resin-ceramics

Sagsoz O, Demirci T, Demirci G, Sagsoz NP, Yildiz M

PURPOSE: The purposes of this study were to evaluate the staining resistance of CAD/CAM resin-ceramics polished with different techniques and to determine the effectiveness of the polishing techniques on resin-ceramics,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Interfacial modulus mapping of layered dental ceramics using nanoindentation

Theocharopoulos AL, Bushby AJ, P'ng KM, Wilson RM, Tanner KE, Cattell MJ

PURPOSE: The aim of this study was to test the modulus of elasticity (E) across the interfaces of yttria stabilized zirconia (YTZP) / veneer multilayers using nanoindentation. MATERIALS AND METHODS: YTZP...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr