Quality Correction for Ir-192 Gamma Rays in Air Kerma Strength Dosimetry Using Cylindrical Ionization Chambers

Jeong DH, Kim JK, Kim KH, Oh YK, Kim SK, Lee KK, Moon SR

  • KMID: 1467610
  • Korean J Med Phys.
  • 2009 Mar;20(1):30-36.
The quality correction in the air kerma dosimetry for Ir-192 using farmer type ionization chambers calibrated by Co-60 quality is required. In this study we determined quality factor (kappa u)...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Study of Radiation Exposure in Proton Therapy Facility

Lee SH, Shin D, Yoon M, Shin J, Rah JE, Kwak J, Park SY, Shin KH, Lee DH, Ahn SH, Kim DY, Cho KH, Lee SB

  • KMID: 1467611
  • Korean J Med Phys.
  • 2009 Mar;20(1):37-42.
Proton therapy facility, which is recently installed at National Cancer Center in Korea, generally produces a large amount of radiation near cyclotron due to the secondary particles and radioisotopes caused...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Commissioning of a micro-MLC (mMLC) for Stereotactic Radiosurgery

Jeong DH, Shin KC, Kim JK, Kim SK, Moon SR, Lee KK

  • KMID: 1467612
  • Korean J Med Phys.
  • 2009 Mar;20(1):43-50.
The 4 bank mico-MLC (mMLC; Acculeaf, Direx, Isral) has been commissioned for clinical use of linac based stereotactic radiosurgery. The geometrical parameters to control the leaves were determined and comparisons...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Analysis of Dose Distribution on Critical Organs for Radiosurgery with CyberKnife Real-Time Tumor Tracking System

Huh HD, Choi SH, Kim WC, Kim HJ, Kim SH, Ji YH, Kim KB, Lee SH, Choi J, Lee R, Shin DO

  • KMID: 1467608
  • Korean J Med Phys.
  • 2009 Mar;20(1):14-20.
We measured the dose distribution for spinal cord and tumor using Gafchromic film, applying 3D and 4D-Treatment Planning for lung tumor within the phantom. A measured dose distribution was compared...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Dose Comparison of Treatment Plans Using Different Ir-192 Sources and Treatment Planning Systems for Intracavitary HDR Brachytherapy

Park DW, Kim YS, Park SH, Choi EK, Kim JH, Lee SW, Song SY, Ahn SD, Noh YJ

  • KMID: 1467606
  • Korean J Med Phys.
  • 2009 Mar;20(1):1-6.
For HDR intracavitary brachytherapy with ovoids and a tandem, we compared the dose discrepancy of treatment plans using two different Ir-192 sources (microSelectron, Varian) and generated on two different treatment...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Chamber to Chamber Variations of a Cylindrical Ionization Chamber for the Calibration of an (192)Ir Brachytherapy Source Based on an Absorbed Dose to Water Standards

Kim SH, Huh H, Choi SH, Kim CH, Min CH, Shin DO, Choi J

  • KMID: 1467607
  • Korean J Med Phys.
  • 2009 Mar;20(1):7-13.
This work is for the preliminary study for the calibration of an (192)Ir brachytherapy source based on an absorbed dose to water standards. In order to calibrate brachytherapy sources based...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Standardization of the Method of Measuring Average Glandular Dose (AGD) and Evaluation of the Breast Composition and Thickness for AGD

Park HS, Kim HJ, Lee CL, Cho HM, Yu AR

  • KMID: 1467609
  • Korean J Med Phys.
  • 2009 Mar;20(1):21-29.
Breast cancer is the most common form of cancer among korean woman. Therefore, the early detection activities of breast cancer such as breast self-examinations, clinical breast examinations, mammography are important....