Clin Orthop Surg.  2023 Aug;15(4):616-626. 10.4055/cios22397.

Do Magnets Have the Potential to Serve as a Stabilizer for the Shoulder Joint in Massive Rotator Cuff Tears?: A Biomechanical Cadaveric Study

Affiliations
  • 1Department of Orthopaedic Surgery, Inha University Hospital, Inha University School of Medicine, Incheon, Korea
  • 2Department of Materials Science and Engineering, Inha University, Incheon, Korea
  • 3Orthopaedic Biomechanics Laboratory, Congress Medical Foundation, Pasadena, CA, USA

Abstract

Background
Disruption of the rotator cuff muscles compromises concavity compression force, which leads to superior migration of the humeral head and loss of stability. A novel idea of using the magnetic force to achieve shoulder stabilization in massive rotator cuff tears (MRCTs) was considered because the magnets can stabilize two separate entities with an attraction force. This study aimed to investigate the biomechanical effect of the magnetic force on shoulder stabilization in MRCTs.
Methods
Seven fresh frozen cadaveric specimens were used with a customized shoulder testing system. Three testing conditions were set up: condition 1, intact rotator cuff without magnets; condition 2, an MRCT without magnets; condition 3, an MRCT with magnets. For each condition, anterior-posterior translation, superior translation, superior migration, and subacromial contact pressure were measured at 0°, 30°, and 60° of abduction. The abduction capability of condition 2 was compared with that of condition 3.
Results
The anterior-posterior and superior translations increased in condition 2; however, they decreased compared to condition 2 when the magnets were applied (condition 3) in multiple test positions and loadings (p <0.05). Abduction capability improved significantly in condition 3 compared with that in condition 2, even for less deltoid loading (p < 0.05).
Conclusions
The magnet biomechanically played a positive role in stabilizing the shoulder joint and enabled abduction with less deltoid force in MRCTs. However, to ensure that the magnet is clinically applicable as a stabilizer for the shoulder joint, it is necessary to thoroughly verify its safety in the human body and to conduct further research on technical challenges.

Keyword

Massive rotator cuff tear; Anatomical shoulder arthroplasty; Magnet; Stabilization; Biomechanics