J Korean Diabetes.  2018 Dec;19(4):224-231. 10.4093/jkd.2018.19.4.224.

Advances in Glucose Monitoring and Insulin Therapy in Intensive Care Unit Patients

Affiliations
  • 1Division of Endocrinology and Metabolism, Department of Internal Medicine, Inje University College of Medicine, Busan, Korea. kimtn031@gmail.com
  • 2Cardiovascular and Metabolic Disease Center, Inje University College of Medicine, Busan, Korea.

Abstract

Since the multicenter Normoglycemia in Intensive Care Evaluation-Survival Using Glucose Algorithm Regulation (NICE-SUGAR) study was published, the pursuit of tight glycemic control (TGC) among intensive care unit (ICU) patients has been seen as counterproductive and moderate glycemic control has become standard practice in ICUs. However, thus far, there is good evidence that hypoglycemia and hyperglycemia are associated with worse outcomes in ICU patients. Recently, the importance of improving time in band and reducing hypoglycemic episodes and glycemic variability has been more recognized. Compared to intermittent monitoring systems, continuous glucose monitoring (CGM) can have greater clinical benefit in terms of the prevention of severe hyperglycemia and hypoglycemia by enabling insulin infusions to be adjusted more rapidly and accurately. In this review, modern methods for glucose control in the ICU are presented, as well as future perspectives including the development of CGM and semiautomated glucose control, such as closed-loop systems.

Keyword

Glucose; Hyperglycemia; Hypoglycemia; Insulin; Intensive care units

MeSH Terms

Critical Care*
Glucose*
Humans
Hyperglycemia
Hypoglycemia
Insulin*
Intensive Care Units*
Glucose
Insulin

Reference

References

1. Capes SE, Hunt D, Malmberg K, Pathak P, Gerstein HC. Stress hyperglycemia and prognosis of stroke in nondiabetic and diabetic patients: a systematic overview. Stroke. 2001; 32:2426–32.
2. Weir CJ, Murray GD, Dyker AG, Lees KR. Is hyperglycaemia an independent predictor of poor outcome after acute stroke? Results of a longterm follow up study. BMJ. 1997; 314:1303–6.
3. Umpierrez GE, Isaacs SD, Bazargan N, You X, Thaler LM, Kitabchi AE. Hyperglycemia: an independent marker of in-hospital mortality in patients with undiagnosed diabetes. J Clin Endocrinol Metab. 2002; 87:978–82.
Article
4. van den Berghe G, Wouters P, Weekers F, Verwaest C, Bruyninckx F, Schetz M, Vlasselaers D, Ferdinande P, Lauwers P, Bouillon R. Intensive insulin therapy in critically ill patients. N Engl J Med. 2001; 345:1359–67.
Article
5. Van den Berghe G, Wilmer A, Hermans G, Meersseman W, Wouters PJ, Milants I, Van Wijngaerden E, Bobbaers H, Bouillon R. Intensive insulin therapy in the medical ICU. N Engl J Med. 2006; 354:449–61.
Article
6. NICE-SUGAR Study Investigators. Finfer S, Chittock DR, Su SY, Blair D, Foster D, Dhingra V, Bellomo R, Cook D, Dodek P, Henderson WR, Hébert PC, Heritier S, Heyland DK, McArthur C, McDonald E, Mitchell I, Myburgh JA, Norton R, Potter J, Robinson BG, Ronco JJ. Intensive versus conventional glucose control in critically ill patients. N Engl J Med. 2009; 360:1283–97.
Article
7. ACE/ADA Task Force on Inpatient Diabetes. American College of Endocrinology and American Diabetes Association Consensus statement on inpatient diabetes and glycemic control. Diabetes Care. 2006; 29:1955–62.
8. Garber AJ, Moghissi ES, Bransome ED Jr, Clark NG, Clement S, Cobin RH, Furnary AP, Hirsch IB, Levy P, Roberts R, Van den Berghe G, Zamudio V. American College of Endocrinology Task Force on Inpatient Diabetes Metabolic Control. American College of Endocrinology position statement on inpatient diabetes and metabolic control. Endocr Pract. 2004; 10:77–82.
Article
9. American Diabetes Association. Standards of medical care in diabetes. Diabetes Care. 2005; 28(Suppl 1):S4–36.
10. Moghissi ES, Korytkowski MT, DiNardo M, Einhorn D, Hellman R, Hirsch IB, Inzucchi SE, IsmailBeigi F, Kirkman MS, Umpierrez GE. American Association of Clinical Endocrinologists; American Diabetes Association. American Association of Clinical Endocrinologists and American Diabetes Association consensus statement on inpatient glycemic control. Diabetes Care. 2009; 32:1119–31.
Article
11. Qaseem A, Humphrey LL, Chou R, Snow V, Shekelle P. Clinical Guidelines Committee of the American College of Physicians. Use of intensive insulin therapy for the management of glycemic control in hospitalized patients: a clinical practice guideline from the American College of Physicians. Ann Intern Med. 2011; 154:260–7.
Article
12. American Diabetes Association. 14. Diabetes care in the hospital: Standards of Medical Care in Diabetes-2018. Diabetes Care. 2018; 41(Suppl 1):S144–51.
13. Heinemann L. Noninvasive glucose monitoring systems: will we ever have such sensors for practical use? J Diabetes Sci Technol. 2007; 1:936–9.
Article
14. Khalil OS. Noninvasive glucose measurement technologies: an update from 1999 to the dawn of the new millennium. Diabetes Technol Ther. 2004; 6:660–97.
Article
15. Pitkin AD, Rice MJ. Challenges to glycemic measurement in the perioperative and critically ill patient: a review. J Diabetes Sci Technol. 2009; 3:1270–81.
Article
16. Corstjens AM, Ligtenberg JJ, van der Horst IC, Spanjersberg R, Lind JS, Tulleken JE, Meertens JH, Zijlstra JG. Accuracy and feasibility of point-of-care and continuous blood glucose analysis in critically ill ICU patients. Crit Care. 2006; 10:R135.
17. Klonoff DC. Intensive insulin therapy in critically ill hospitalized patients: making it safe and effective. J Diabetes Sci Technol. 2011; 5:755–67.
Article
18. Fahy BG, Sheehy AM, Coursin DB. Glucose control in the intensive care unit. Crit Care Med. 2009; 37:1769–76.
Article
19. Alter D, Deines G. Tight glycemic control and point-of-care testing. Clin Lab Med. 2009; 29:511–22.
Article
20. Karon BS, Gandhi GY, Nuttall GA, Bryant SC, Schaff HV, McMahon MM, Santrach PJ. Accuracy of roche accu-chek inform whole blood capillary, arterial, and venous glucose values in patients receiving intensive intravenous insulin therapy after cardiac surgery. Am J Clin Pathol. 2007; 127:919–26.
Article
21. Kanji S, Buffie J, Hutton B, Bunting PS, Singh A, McDonald K, Fergusson D, McIntyre LA, Hebert PC. Reliability of point-of-care testing for glucose measurement in critically ill adults. Crit Care Med. 2005; 33:2778–85.
Article
22. Joseph JI, Hipszer B, Mraovic B, Chervoneva I, Joseph M, Grunwald Z. Clinical need for continuous glucose monitoring in the hospital. J Diabetes Sci Technol. 2009; 3:1309–18.
Article
23. Mraovic B. Analysis: continuous glucose monitoring during intensive insulin therapy. J Diabetes Sci Technol. 2009; 3:960–3.
Article
24. Dassau E, Cameron F, Lee H, Bequette BW, Zisser H, Jovanovic L, Chase HP, Wilson DM, Buckingham BA, Doyle FJ 3rd. Real-time hypoglycemia prediction suite using continuous glucose monitoring: a safety net for the artificial pancreas. Diabetes Care. 2010; 33:1249–54.
25. Davey RJ, Jones TW, Fournier PA. Effect of short-term use of a continuous glucose monitoring system with a realtime glucose display and a low glucose alarm on incidence and duration of hypoglycemia in a home setting in type 1 diabetes mellitus. J Diabetes Sci Technol. 2010; 4:1457–64.
Article
26. Egi M, Bellomo R, Stachowski E, French CJ, Hart G. Variability of blood glucose concentration and short-term mortality in critically ill patients. Anesthesiology. 2006; 105:244–52.
Article
27. Krinsley JS, Egi M, Kiss A, Devendra AN, Schuetz P, Maurer PM, Schultz MJ, van Hooijdonk RT, Kiyoshi M, Mackenzie IM, Annane D, Stow P, Nasraway SA, Holewinski S, Holzinger U, Preiser JC, Vincent JL, Bellomo R. Diabetic status and the relation of the three domains of glycemic control to mortality in critically ill patients: an international multicenter cohort study. Crit Care. 2013; 17:R37.
Article
28. Lanspa MJ, Dickerson J, Morris AH, Orme JF, Holmen J, Hirshberg EL. Coefficient of glucose variation is independently associated with mortality in critically ill patients receiving intravenous insulin. Crit Care. 2014; 18:R86.
Article
29. Preiser JC, Chase JG, Hovorka R, Joseph JI, Krinsley JS, De Block C, Desaive T, Foubert L, Kalfon P, Pielmeier U, Van Herpe T, Wernerman J. Glucose control in the ICU: a continuing story. J Diabetes Sci Technol. 2016; 10:1372–81.
30. Goldberg PA, Siegel MD, Sherwin RS, Halickman JI, Lee M, Bailey VA, Lee SL, Dziura JD, Inzucchi SE. Implementation of a safe and effective insulin infusion protocol in a medical intensive care unit. Diabetes Care. 2004; 27:461–7.
Article
31. Evans A, Le Compte A, Tan CS, Ward L, Steel J, Pretty CG, Penning S, Suhaimi F, Shaw GM, Desaive T, Chase JG. Stochastic targeted (STAR) glycemic control: design, safety, and performance. J Diabetes Sci Technol. 2012; 6:102–15.
Article
32. Van Herpe T, Mesotten D, Wouters PJ, Herbots J, Voets E, Buyens J, De Moor B, Van den Berghe G. LOGIC-insulin algorithm-guided versus nurse-directed blood glucose control during critical illness: the LOGIC-1 singlecenter, randomized, controlled clinical trial. Diabetes Care. 2013; 36:188–94.
33. Pachler C, Plank J, Weinhandl H, Chassin LJ, Wilinska ME, Kulnik R, Kaufmann P, Smolle KH, Pilger E, Pieber TR, Ellmerer M, Hovorka R. Tight glycaemic control by an automated algorithm with time-variant sampling in medical ICU patients. Intensive Care Med. 2008; 34:1224–30.
Article
34. Vogelzang M, Zijlstra F, Nijsten MW. Design and implementation of GRIP: a computerized glucose control system at a surgical intensive care unit. BMC Med Inform Decis Mak. 2005; 5:38.
Article
35. Pielmeier U, Andreassen S, Juliussen B, Chase JG, Nielsen BS, Haure P. The Glucosafe system for tight glycemic control in critical care: a pilot evaluation study. J Crit Care. 2010; 25:97–104.
Article
36. Kalfon P, Giraudeau B, Ichai C, Guerrini A, Brechot N, Cinotti R, Dequin PF, Riu-Poulenc B, Montravers P, Annane D, Dupont H, Sorine M, Riou B. CGAO-REA Study Group. Tight computerized versus conventional glucose control in the ICU: a randomized controlled trial. Intensive Care Med. 2014; 40:171–81.
Article
37. Christiansen JS, Svendsen PA, Deckert T. Insulin treatment and state of control before, during, and after connection to a glucose controlled insulin infusion system (Biostator). Horm Metab Res Suppl. 1979; 8:131–4.
38. Yatabe T, Yamazaki R, Kitagawa H, Okabayashi T, Yamashita K, Hanazaki K, Yokoyama M. The evaluation of the ability of closed-loop glycemic control device to maintain the blood glucose concentration in intensive care unit patients. Crit Care Med. 2011; 39:575–8.
Article
39. Leelarathna L, English SW, Thabit H, Caldwell K, Allen JM, Kumareswaran K, Wilinska ME, Nodale M, Mangat J, Evans ML, Burnstein R, Hovorka R. Feasibility of fully automated closed-loop glucose control using continuous subcutaneous glucose measurements in critical illness: a randomized controlled trial. Crit Care. 2013; 17:R159.
Article
40. Okabayashi T, Shima Y, Sumiyoshi T, Kozuki A, Tokumaru T, Iiyama T, Sugimoto T, Kobayashi M, Yokoyama M, Hanazaki K. Intensive versus intermediate glucose control in surgical intensive care unit patients. Diabetes Care. 2014; 37:1516–24.
Article
Full Text Links
  • JKD
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr