J Korean Shoulder Elbow Soc.  2007 Jun;10(1):99-105.

Dynamic Morphologic Study of the Ulnar Nerve Around the Elbow Using Ultrasonography

Affiliations
  • 1Department of Orthopedic Surgery, Collage of Medicine, Kyungpook National University, Korea. jeonchoi@chol.com

Abstract

Purpose: The morphological study and dynamic stability of the ulnar nerve around the elbow joint was investigated in asymptomatic normal population using ultrasonography. The purpose of this study is to provide fundamental data for ultrasonographic diagnosis of ulnar neuropathy in cubital tunnel syndrome.
Materials and Methods
Fifty cases of 25 healthy male volunteers, aged between 20 to 30 years, included in this study. High resolution 7.5 MHz linear probe was used to examine the ulnar nerve in axial and longitudinal views. In a longitudinal view, the course, position and the thickness of nerve were monitored, the diameter of ulnar nerve and dynamic stability at elbow flexion and extension were measured in an axial view at four different points; 1cm proximal to medial epicondyle, behind the medial epicondyle, entrance to Osborne ligament, and 1cm distal to Osborne ligament.
Results
The short diameters of ulnar nerve at elbow extension at four anatomic points were 2.66 mm, 2.97 mm, 2.64 mm, and 2.69 mm and the long diameters were 4.61 mm, 4.56 mm, 4.36 mm, and 4.37 mm, which showed no significant change at each point. However, at elbow flexion, the short diameters were changed to 2.72 mm, 2.34 mm, 2.65 mm, and 2.41 mm and the long diameters into 4.49 mm, 5.40 mm, 4.16 mm, and 4.66 mm. At elbow flexion, significant morphologic change was observed in the medial epicondyle area, and the diameter of the ulnar nerve was shortest at the entrance of Osborne ligament both at flexion and extension. In terms of dynamic stability, nine subluxations and seven dislocations were observed.
Conclusion
This study shows dynamic instability and a morphological change of long and short diameters of ulnar nerve at flexion and extension in a normal person, which should be considered in the ultrasonographic diagnosis of ulnar neuropathy.

Keyword

Ulnar neuropathy; Cubital tunnel syndrome; Ultrasonography; Dynamic instability

MeSH Terms

Cubital Tunnel Syndrome
Diagnosis
Dislocations
Elbow Joint
Elbow*
Humans
Ligaments
Male
Ulnar Nerve*
Ulnar Neuropathies
Ultrasonography*
Volunteers
Full Text Links