Korean J Gastrointest Endosc.  2009 Feb;38(2):85-89.

A Case of Removing an Esophageal Sharp Foreign Body Using a Surgical Glove

Affiliations
  • 1Department of Internal Medicine, Kosin University College of Medicine, Busan, Korea. drkkj@paran.com

Abstract

Foreign bodies with a sharp margin in the esophagus are often associated with serious complications, such as bleeding, perforation and mediastinitis in the middle of endoscopic removal, as well as impaction in the esophagus wall. Therefore, safe extraction for such patients is essential. The techniques that are performed with an endoscope have been designed with using a protector hood and overtube. Yet the former is not available in Korea, and the later is uncomfortable and limited in diameter. Press-through-packs (PTPs) are commonly used as a package for drugs and they also usually cause esophageal impaction because they have sharp edges. We report here on a case of an impacted PTP in the upper esophagus, and this was successfully extracted endoscopically with using a surgical glove, which is a better safe alternative to above mentioned removal items.

Keyword

Foreign bodies; Sharp margin; Esophagus; Press-through-packs; Surgical glove

MeSH Terms

Endoscopes
Esophagus
Foreign Bodies
Gloves, Surgical
Hemorrhage
Humans
Korea
Mediastinitis
Full Text Links
  • KJGE
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr